{"id":10162,"date":"2017-06-11T23:57:03","date_gmt":"2017-06-11T23:57:03","guid":{"rendered":"http:\/\/mazdaman.x10host.com\/sm355859\/"},"modified":"2017-06-11T23:57:03","modified_gmt":"2017-06-11T23:57:03","slug":"sm355859","status":"publish","type":"page","link":"https:\/\/chroot-me.in\/16ND\/sm355859\/","title":{"rendered":"DTC U2300:55 [CONNECTIVITY MASTER UNIT]"},"content":{"rendered":"<div class=\"node node SERVICE_MANUALS\">\n    <\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT c2\">\n<div class=\"content\">\n          <link rel=\"stylesheet\" type=\"text\/css\" href=\"style.css\" media=\"screen\"><a class=\"prevPage\" href=\"SM355858\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM355860\">Next &gt;<\/a><\/p>\n<h2>2016 &#8211; MX-5 &#8211; Body and Accessories<\/h2>\n<p><a name=\"id0902n7106600\" id=\"id0902n7106600\"><\/a><\/p>\n<h3>DTC U2300:55 [CONNECTIVITY MASTER UNIT]<\/h3>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Description<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Instrument cluster configuration not implemented<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Detection condition<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>The connectivity master unit (CMU) detected any of the following conditions with the ignition switched to ACC or ON (engine off or on).<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Instrument cluster configuration not read<\/p>\n<\/li>\n<li>\n<p>Configuration data cannot be written to connectivity master unit (CMU) memory.<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Fail-safe<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Not applicable<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Possible cause<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b><span class=\"c1\">NOTE:<\/span><\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>To correctly write the configuration data, which is sent from the instrument cluster to the connectivity master unit (CMU), to the connectivity master unit (CMU), <b>30 s or more<\/b> must have elapsed since the ignition was switched ON (engine off or on).<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Instrument cluster configuration is not completed.<\/p>\n<\/li>\n<li>\n<p>Instrument cluster malfunction<\/p>\n<\/li>\n<li>\n<p>Connectivity master unit (CMU) malfunction<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>System wiring diagram<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Not applicable<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <b>Diagnostic Procedure<\/b><\/p>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Step<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p>Inspection<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Action<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>1<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY ALL SYSTEM DTCs<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Clear the DTC for the connectivity master unit (CMU) using the M-MDS.<\/p>\n<p>(See <a href=\"SM355864\">CLEARING DTC [CONNECTIVITY MASTER UNIT]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Switch the ignition ON (engine off or on) and wait for <b>37 s or more<\/b>.<\/p>\n<\/li>\n<li>\n<p>Perform a CMDTC self-test using the M-MDS.<\/p>\n<p>(See <a href=\"SM355862\">DTC INSPECTION [CONNECTIVITY MASTER UNIT]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Are there any modules other than the connectivity master unit (CMU) displaying DTC U2300:55?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step.<\/p>\n<p>(See <a href=\"SM356365\">INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA)<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 3.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>2<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY ALL SYSTEM DTCs AGAIN<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Clear the DTC for the connectivity master unit (CMU) using the M-MDS.<\/p>\n<p>(See <a href=\"SM355864\">CLEARING DTC [CONNECTIVITY MASTER UNIT]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Switch the ignition ON (engine off or on) and wait for <b>37 s or more<\/b>.<\/p>\n<\/li>\n<li>\n<p>Perform a CMDTC self-test using the M-MDS.<\/p>\n<p>(See <a href=\"SM355862\">DTC INSPECTION [CONNECTIVITY MASTER UNIT]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Are there any modules other than the connectivity master unit (CMU) displaying DTC U2300:55?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the instrument cluster, then go to the next step.<\/p>\n<p>(See <a href=\"SM356358\">INSTRUMENT CLUSTER REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>3<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY THAT REPAIRS HAVE BEEN COMPLETED<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Clear the DTC for the connectivity master unit (CMU) using the M-MDS.<\/p>\n<p>(See <a href=\"SM355864\">CLEARING DTC [CONNECTIVITY MASTER UNIT]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Switch the ignition ON (engine off or on) and wait for <b>37 s or more<\/b>.<\/p>\n<\/li>\n<li>\n<p>Retrieve the connectivity master unit (CMU) DTCs using the M-MDS.<\/p>\n<p>(See <a href=\"SM355862\">DTC INSPECTION [CONNECTIVITY MASTER UNIT]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Is the same DTC displayed?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the connectivity master unit (CMU), then go to the next step.<\/p>\n<p>(See <a href=\"SM356302\">CONNECTIVITY MASTER UNIT (CMU) REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>4<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY IF OTHER DTCs DISPLAYED<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Are any other DTCs displayed?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.<\/p>\n<p>(See <a href=\"SM355863\">DTC TABLE [CONNECTIVITY MASTER UNIT]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>DTC troubleshooting completed.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a class=\"prevPage\" href=\"SM355858\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM355860\">Next &gt;<\/a><\/p>\n<div align=\"right\">\n            <a href=\"\"#\">Back to Top<\/a>\n          <\/div>\n<div align=\"center\">\n            <em>\u00a9 2014 Mazda North American Operations, U.S.A.<\/em>\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&lt; Previous Next &gt; 2016 &#8211; MX-5 &#8211; Body and Accessories DTC U2300:55 [CONNECTIVITY MASTER UNIT] Description Instrument cluster configuration not implemented Detection condition The connectivity master unit (CMU) detected any of the following conditions with the ignition switched to ACC or ON (engine off or on). Instrument cluster configuration not read Configuration data cannot be written to connectivity master unit (CMU) memory. Fail-safe Not applicable Possible cause NOTE: To correctly write the configuration data, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-10162","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/10162","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/comments?post=10162"}],"version-history":[{"count":0,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/10162\/revisions"}],"wp:attachment":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/media?parent=10162"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}