{"id":10813,"date":"2017-06-11T23:56:47","date_gmt":"2017-06-11T23:56:47","guid":{"rendered":"http:\/\/mazdaman.x10host.com\/sm361341\/"},"modified":"2017-06-11T23:56:47","modified_gmt":"2017-06-11T23:56:47","slug":"sm361341","status":"publish","type":"page","link":"https:\/\/chroot-me.in\/16ND\/sm361341\/","title":{"rendered":"DTC U3000:4B [EVP CONTROL UNIT]"},"content":{"rendered":"<div class=\"node node SERVICE_MANUALS\">\n    <\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT c2\">\n<div class=\"content\">\n          <link rel=\"stylesheet\" type=\"text\/css\" href=\"style.css\" media=\"screen\"><a class=\"prevPage\" href=\"SM361340\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM361342\">Next &gt;<\/a><\/p>\n<h2>2016 &#8211; MX-5 &#8211; Brakes<\/h2>\n<p><a name=\"id040251840500\" id=\"id040251840500\"><\/a><\/p>\n<h3>DTC U3000:4B [EVP CONTROL UNIT]<\/h3>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>DTC<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>U3000:4B<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>EVP control unit: high internal temperature<\/b><\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p><b>DETECTION CONDITION<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>A circuit board temperature inside the EVP control unit of <b>130 degrees C {266 degrees F} or more<\/b> is detected.<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p><b>FAIL-SAFE FUNCTION<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Refer to \u201cFail-safe function table\u201d. (See <a href=\"SM352916\">DTC TABLE [EVP CONTROL UNIT]<\/a>.)<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p><b>POSSIBLE CAUSE<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Continuous use of electric vacuum pump under high engine compartment temperature<\/p>\n<\/li>\n<li>\n<p>Temperature sensor (built-in EVP control unit) malfunction<\/p>\n<\/li>\n<li>\n<p>EVP control unit malfunction<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p><b>SYSTEM WIRING DIAGRAM<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>\u2014<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <b>Diagnostic Procedure<\/b><\/p>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Step<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p>Inspection<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Action<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>1<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n                  <b>RECORD SNAPSHOT DATA AND DIAGNOSTIC MONITORING TEST RESULTS TO UTILIZE WITH REPEATABILITY VERIFICATION<\/b><\/p>\n<p><b><span class=\"c1\">NOTE:<\/span><\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Recording can be facilitated using the screen capture function of the PC.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Record the snapshot data and DIAGNOSTIC MONITORING TEST RESULTS (fuel system related) on the repair order.<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>\u2014<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>2<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY IF DIAGNOSTIC RESULT IS AFFECTED BY OTHER RELATED DTCs OCCURRING<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Using the M-MDS, perform the EVP control unit DTC inspection.<\/p>\n<p>(See <a href=\"SM352914\">DTC INSPECTION [EVP CONTROL UNIT]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Is any other DTC or pending code stored?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the applicable DTC inspection.<\/p>\n<p>(See <a href=\"SM352916\">DTC TABLE [EVP CONTROL UNIT]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>3<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY DTC REPEATABILITY<\/b><\/p>\n<p><b><span class=\"c1\">NOTE:<\/span><\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>When clearing the DTC, the snap shot data is also cleared at the same time. Snap shot data is recorded if it is not recorded in Step 1.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Using the M-MDS, clear the DTC from the EVP control unit.<\/p>\n<p>(See <a href=\"SM352915\">CLEARING DTC [EVP CONTROL UNIT]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Switch the ignition ON (engine off).<\/p>\n<\/li>\n<li>\n<p>Using the M-MDS, perform the EVP control unit DTC inspection.<\/p>\n<p>(See <a href=\"SM352914\">DTC INSPECTION [EVP CONTROL UNIT]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Are any DTCs present?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n                      <b>DTC U3000:4B is displayed:<\/b><\/p>\n<li>\n<p>Replace the EVP control unit, then go to the next step.<\/p>\n<p>(See <a href=\"SM352992\">EVP CONTROL UNIT REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>DTC other than U3000:4B is displayed:<\/b><\/p>\n<li>\n<p>Go to the applicable DTC inspection.<\/p>\n<p>(See <a href=\"SM352916\">DTC TABLE [EVP CONTROL UNIT]<\/a>.)<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>DTC troubleshooting completed.<\/p>\n<p>Explain to the customer that there are no malfunctions with the vehicle based on the contents of the servicing.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>4<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY NO DTC IS PRESENT<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Are any DTCs present?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the applicable DTC inspection.<\/p>\n<p>(See <a href=\"SM352916\">DTC TABLE [EVP CONTROL UNIT]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>DTC troubleshooting completed.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a class=\"prevPage\" href=\"SM361340\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM361342\">Next &gt;<\/a><\/p>\n<div align=\"right\">\n            <a href=\"\"#\">Back to Top<\/a>\n          <\/div>\n<div align=\"center\">\n            <em>\u00a9 2014 Mazda North American Operations, U.S.A.<\/em>\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&lt; Previous Next &gt; 2016 &#8211; MX-5 &#8211; Brakes DTC U3000:4B [EVP CONTROL UNIT] DTC U3000:4B EVP control unit: high internal temperature DETECTION CONDITION A circuit board temperature inside the EVP control unit of 130 degrees C {266 degrees F} or more is detected. FAIL-SAFE FUNCTION Refer to \u201cFail-safe function table\u201d. (See DTC TABLE [EVP CONTROL UNIT].) POSSIBLE CAUSE Continuous use of electric vacuum pump under high engine compartment temperature Temperature sensor (built-in EVP control [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-10813","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/10813","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/comments?post=10813"}],"version-history":[{"count":0,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/10813\/revisions"}],"wp:attachment":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/media?parent=10813"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}