{"id":8523,"date":"2017-06-08T04:12:56","date_gmt":"2017-06-08T04:12:56","guid":{"rendered":"http:\/\/mazdaman.x10host.com\/sh13236\/"},"modified":"2017-06-08T04:12:56","modified_gmt":"2017-06-08T04:12:56","slug":"sh13236","status":"publish","type":"page","link":"https:\/\/chroot-me.in\/16ND\/sh13236\/","title":{"rendered":"BLOWER FAN CONTROLLER"},"content":{"rendered":"<div class=\"node node SERVICE_HIGHLIGHTS\">\n    <\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT c1\">\n<div class=\"content\">\n          <link rel=\"stylesheet\" type=\"text\/css\" href=\"style.css\" media=\"screen\"><a class=\"prevPage\" href=\"SH13235\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SH13237\">Next &gt;<\/a><\/p>\n<h2>2016 &#8211; MX-5 &#8211; HVAC<\/h2>\n<p><a name=\"id071100001500\" id=\"id071100001500\"><\/a><\/p>\n<h3>BLOWER FAN CONTROLLER<\/h3>\n<p><a name=\"id07110000150001\" id=\"id07110000150001\"><\/a><\/p>\n<h4>Purpose<\/h4>\n<ul type=\"disc\">\n<li>\n<p>The blower fan controller controls the blower motor rotation speed.<\/p>\n<\/li>\n<\/ul>\n<p>          <a name=\"id07110000150002\" id=\"id07110000150002\"><\/a><\/p>\n<h4>Functions<\/h4>\n<ul type=\"disc\">\n<li>\n<p>By placing the fin in the upper part of the blower fan controller, temperature increase in the internal circuit is suppressed.<\/p>\n<\/li>\n<li>\n<p>The blower fan controller is equipped with a fail-safe function for the purpose of protecting the internal circuits.<\/p>\n<\/li>\n<\/ul>\n<p>          <a name=\"id07110000150003\" id=\"id07110000150003\"><\/a><\/p>\n<h4>Construction<\/h4>\n<ul type=\"disc\">\n<li>\n<p>The blower fan controller is located on the A\/C unit.<\/p>\n<\/li>\n<\/ul>\n<p align=\"center\"><a href=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUN00000676.GIF\"><img decoding=\"async\" align=\"absmiddle\" border=\"0\" src=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUN00000676.GIF\"><\/a><\/p>\n<p><a name=\"id07110000150004\" id=\"id07110000150004\"><\/a><\/p>\n<h5>Power MOS FET circuit<\/h5>\n<ul type=\"disc\">\n<li>\n<p>When voltage of the threshold or more is applied to the gate, a large amount of electricity flows between the drain and source and the power MOS FET turns on.<\/p>\n<p align=\"center\"><a href=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUN00000452.GIF\"><img decoding=\"async\" align=\"absmiddle\" border=\"0\" src=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUN00000452.GIF\"><\/a><\/p>\n<\/li>\n<\/ul>\n<p>          <a name=\"id07110000150005\" id=\"id07110000150005\"><\/a><\/p>\n<h4>Operation<\/h4>\n<ul type=\"disc\">\n<li>\n<p>For the blower fan controller operation, refer to the [BLOWER SYSTEM]. (See <a href=\"SH13234\">BLOWER SYSTEM<\/a>.)<\/p>\n<\/li>\n<\/ul>\n<p>          <a name=\"id07110000150006\" id=\"id07110000150006\"><\/a><\/p>\n<h4>Fail-safe<\/h4>\n<ul type=\"disc\">\n<li>\n<p>The blower fan controller stops output for a certain period of time when the following conditions are met.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Motor lock<\/p>\n<\/li>\n<ul type=\"disc\">\n<li>\n<p>The blower motor locks and over-current flows.<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Abnormal temperature<\/p>\n<\/li>\n<ul type=\"disc\">\n<li>\n<p>The power MOS FET increases temperature abnormally due to half-lock (over-current of a level such that motor-lock is not detected) of the blower motor.<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<\/ul>\n<p>          <a class=\"prevPage\" href=\"SH13235\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SH13237\">Next &gt;<\/a><\/p>\n<div align=\"right\">\n            <a href=\"\"#\">Back to Top<\/a>\n          <\/div>\n<div align=\"center\">\n            <em>\u00a9 2014 Mazda North American Operations, U.S.A.<\/em>\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&lt; Previous Next &gt; 2016 &#8211; MX-5 &#8211; HVAC BLOWER FAN CONTROLLER Purpose The blower fan controller controls the blower motor rotation speed. Functions By placing the fin in the upper part of the blower fan controller, temperature increase in the internal circuit is suppressed. The blower fan controller is equipped with a fail-safe function for the purpose of protecting the internal circuits. Construction The blower fan controller is located on the A\/C unit. Power [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-8523","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/8523","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/comments?post=8523"}],"version-history":[{"count":0,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/8523\/revisions"}],"wp:attachment":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/media?parent=8523"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}