{"id":8927,"date":"2017-06-11T23:58:14","date_gmt":"2017-06-11T23:58:14","guid":{"rendered":"http:\/\/mazdaman.x10host.com\/sm352594\/"},"modified":"2017-06-11T23:58:14","modified_gmt":"2017-06-11T23:58:14","slug":"sm352594","status":"publish","type":"page","link":"https:\/\/chroot-me.in\/16ND\/sm352594\/","title":{"rendered":"DTC P2504:00 [PCM (SKYACTIV-G 2.0)]"},"content":{"rendered":"<div class=\"node node SERVICE_MANUALS\">\n    <\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT c2\">\n<div class=\"content\">\n          <link rel=\"stylesheet\" type=\"text\/css\" href=\"style.css\" media=\"screen\"><a class=\"prevPage\" href=\"SM352593\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM352595\">Next &gt;<\/a><\/p>\n<h2>2016 &#8211; MX-5 &#8211; Engine<\/h2>\n<p><a name=\"id0102i5709700\" id=\"id0102i5709700\"><\/a><\/p>\n<h3>DTC P2504:00 [PCM (SKYACTIV-G 2.0)]<\/h3>\n<p><b><span class=\"c1\">NOTE:<\/span><\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>To determine the malfunctioning part, proceed with the diagnostics from &#8220;Function Inspection Using M-MDS&#8221;.<\/p>\n<\/li>\n<\/ul>\n<p>          <a name=\"id0102i570970001\" id=\"id0102i570970001\"><\/a><\/p>\n<h4>Details On DTCs<\/h4>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>DESCRIPTION<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p>Generator system: Voltage generated by generator is high<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"6\" colspan=\"NaN\">\n<p><b>DETECTION CONDITION<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Determination conditions<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>The voltage generated by the generator is <b>18.5 V or higher<\/b> or the battery voltage is <b>16 V or higher<\/b> for a continuous specified time.<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Preconditions<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>While engine is running<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Malfunction determination period<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p><b>5 s<\/b> period<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Drive cycle<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>1<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Self test type<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>CMDTC self test<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Sensor used<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>PCM<\/p>\n<\/li>\n<li>\n<p>Generator<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>FAIL-SAFE FUNCTION<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<ul type=\"disc\">\n<li>\n<p>Generator control is inhibited.<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>VEHICLE STATUS WHEN DTCs ARE OUTPUT<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<ul type=\"disc\">\n<li>\n<p>A warning message is displayed in the display. (With center display)<\/p>\n<\/li>\n<li>\n<p>Illuminates charging system warning light.<\/p>\n<\/li>\n<li>\n<p>The following vehicle conditions differ depending on the type of malfunction:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Vehicle shock may occur due to generator load.<\/p>\n<\/li>\n<li>\n<p>Idling feel due to generator-stop may occur.<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>POSSIBLE CAUSE<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<ul type=\"disc\">\n<li>\n<p>Poor connection of the following parts:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Battery<\/p>\n<\/li>\n<li>\n<p>Generator<\/p>\n<\/li>\n<li>\n<p>PCM<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Connector or terminal malfunction of the following parts:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Battery<\/p>\n<\/li>\n<li>\n<p>Generator<\/p>\n<\/li>\n<li>\n<p>PCM<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Short to power supply in wiring harness between battery positive terminal and generator terminal 1A<\/p>\n<\/li>\n<li>\n<p>STR\/ALT 200 A fuse malfunction<\/p>\n<\/li>\n<li>\n<p>Open circuit in wiring harness between battery positive terminal and generator terminal 1A<\/p>\n<\/li>\n<li>\n<p>Generator malfunction<\/p>\n<\/li>\n<li>\n<p>Battery malfunction<\/p>\n<\/li>\n<li>\n<p>PCM malfunction<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a name=\"id0102i570970002\" id=\"id0102i570970002\"><\/a><\/p>\n<h4>System Wiring Diagram<\/h4>\n<p align=\"center\"><a href=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUW00003796.GIF\"><img decoding=\"async\" align=\"absmiddle\" border=\"0\" src=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUW00003796.GIF\"><\/a><\/p>\n<p><a name=\"id0102i570970003\" id=\"id0102i570970003\"><\/a><\/p>\n<h4>Function Explanation (DTC Detection Outline)<\/h4>\n<ul type=\"disc\">\n<li>\n<p>When the charge\/discharge circuit for the power supplying the vehicle is normal, the vehicle will operate normally.<\/p>\n<\/li>\n<li>\n<p>The PCM determines an over-charge malfunction by detecting that the generator terminal voltage or battery terminal voltage are abnormally high, and verification of vehicle malfunctions\/safety assurance is performed.<\/p>\n<\/li>\n<\/ul>\n<p>          <a name=\"id0102i570970004\" id=\"id0102i570970004\"><\/a><\/p>\n<h4>Repeatability Verification Procedure<\/h4>\n<ul>\n<li>\n<p>Clear the DTC from the PCM memory using the M-MDS. (See <a href=\"SM352622\">CLEARING DTC [PCM (SKYACTIV-G 2.0)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Start the engine.<\/p>\n<\/li>\n<li>\n<p>Leave for <b>30 s<\/b> while idling with no electrical load.<\/p>\n<\/li>\n<li>\n<p>Leave for <b>30 s<\/b> while idling with high electrical load.<\/p>\n<\/li>\n<\/ul>\n<p>          <a name=\"id0102i570970005\" id=\"id0102i570970005\"><\/a><\/p>\n<h4>PID Item\/Simulation Item Used In Diagnosis<\/h4>\n<ul type=\"disc\">\n<li>\n<p>Not applicable<\/p>\n<\/li>\n<\/ul>\n<p>          <a name=\"id0102i570970006\" id=\"id0102i570970006\"><\/a><\/p>\n<h4>Function Inspection Using M-MDS<\/h4>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>STEP<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>INSPECTION<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>RESULTS<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>ACTION<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>1<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n                  <b>PURPOSE: RECORD VEHICLE STATUS AT TIME OF DTC DETECTION TO UTILIZE WITH REPEATABILITY VERIFICATION<\/b><\/p>\n<p><b><span class=\"c1\">NOTE:<\/span><\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Recording can be facilitated using the screen capture function of the PC.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Record the snapshot data on the repair order.<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>???<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the troubleshooting procedure to perform the procedure from Step 1.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a name=\"id0102i570970007\" id=\"id0102i570970007\"><\/a><\/p>\n<h4>Troubleshooting Diagnostic Procedure<\/h4>\n<ul type=\"disc\">\n              <b>Intention of troubleshooting procedure<\/b><\/p>\n<li>\n<p>Step 1???6<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Perform an inspection of each signal transmission system.<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Step 7<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Perform a unit inspection of the generator.<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Step 8???10<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Verify that the primary malfunction is resolved and there are no other malfunctions.<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>STEP<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>INSPECTION<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>RESULTS<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>ACTION<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>1<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>PURPOSE: VERIFY RELATED REPAIR INFORMATION AVAILABILITY<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Verify related Service Bulletins and\/or on-line repair information availability.<\/p>\n<\/li>\n<li>\n<p>Is any related repair information available?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Perform repair or diagnosis according to the available repair information.<\/p>\n<ul type=\"disc\">\n<li>\n<p>If the vehicle is not repaired, go to the next step.<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>2<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>PURPOSE: VERIFY IF POOR CONNECTION OF EACH PART AFFECTS DIAGNOSTIC RESULTS<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Switch the ignition off.<\/p>\n<\/li>\n<li>\n<p>Inspect the connection condition (part installation condition, connector connection condition) for the following parts:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Battery<\/p>\n<\/li>\n<li>\n<p>Generator<\/p>\n<\/li>\n<li>\n<p>PCM<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is the connection condition (part installation condition, connector connection condition) for each part normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Connect each part or the connector correctly, then go to Step 8.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>3<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>PURPOSE: VERIFY IF CONNECTOR DAMAGE OF EACH PART AFFECTS DIAGNOSTIC RESULTS<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the connector of the following parts.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Battery<\/p>\n<\/li>\n<li>\n<p>Generator<\/p>\n<\/li>\n<li>\n<p>PCM<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Inspect for poor connection (such as damaged\/pulled-out pins, corrosion).<\/p>\n<\/li>\n<li>\n<p>Is there any malfunction?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the connector and\/or terminals, then go to Step 8.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>4<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>PURPOSE: VERIFY IF SHORT TO POWER SUPPLY IN GENERATOR CHARGE\/DISCHARGE CIRCUIT AFFECTS DIAGNOSTIC RESULTS<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Verify that the battery, generator and PCM connectors are disconnected.<\/p>\n<\/li>\n<li>\n<p>Switch the ignition ON (engine off).<\/p>\n<p><b><span class=\"c1\">NOTE:<\/span><\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Another DTC may be stored by the PCM detecting an open circuit.<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li>\n<p>Measure the voltage at the generator terminal 1A (wiring harness-side).<\/p>\n<\/li>\n<li>\n<p>Is the voltage <b>0 V<\/b>?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between battery positive terminal and generator terminal 1A.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness which has a short to power supply.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 8.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>5<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>PURPOSE: INSPECT FUSE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Switch the ignition off.<\/p>\n<\/li>\n<li>\n<p>Remove the STR\/ALT 200 A fuse.<\/p>\n<\/li>\n<li>\n<p>Inspect the STR\/ALT 200 A fuse.<\/p>\n<\/li>\n<li>\n<p>Is there any malfunction?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>If the fuse is blown:<\/p>\n<ul type=\"disc\">\n<li>\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between battery positive terminal and generator terminal 1A.<\/p>\n<\/li>\n<ul type=\"square\">\n                          <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"square\">\n                          <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness which has a short to ground.<\/p>\n<\/li>\n<li>\n<p>Replace the fuse.<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<p>If the fuse is damaged:<\/p>\n<ul type=\"disc\">\n<li>\n<p>Replace the fuse.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 8.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Reinstall the STR\/ALT 200 A fuse, then go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>6<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>PURPOSE: VERIFY IF OPEN CIRCUIT IN GENERATOR CHARGE\/DISCHARGE CIRCUIT AFFECTS DIAGNOSTIC RESULTS<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Verify that the battery, generator and PCM connectors are disconnected.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity between battery positive terminal (wiring harness-side) and generator terminal 1A (wiring harness-side).<\/p>\n<\/li>\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between battery positive terminal and generator terminal 1A.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness which has an open circuit.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 8.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>7<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>PURPOSE: DETERMINE INTEGRITY OF GENERATOR<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect the generator.<\/p>\n<p>(See <a href=\"SM352778\">GENERATOR INSPECTION [SKYACTIV-G 2.0]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Is there any malfunction?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the generator, then go to the next step.<\/p>\n<p>(See <a href=\"SM352777\">GENERATOR REMOVAL\/INSTALLATION [SKYACTIV-G 2.0]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>8<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n                  <b>PURPOSE: VERIFY CONDITIONS OF BATTERY<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect the battery.<\/p>\n<p>(See <a href=\"SM352781\">BATTERY INSPECTION<\/a>.)<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>???<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Follow the inspection instructions, then go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>9<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>PURPOSE: VERIFICATION OF VEHICLE REPAIR COMPLETION<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Always reconnect all disconnected connectors.<\/p>\n<\/li>\n<li>\n<p>Clear the DTC from the PCM memory using the M-MDS.<\/p>\n<p>(See <a href=\"SM352622\">CLEARING DTC [PCM (SKYACTIV-G 2.0)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Implement the repeatability verification procedure.<\/p>\n<p>(See <a href=\"\"#id0102i570970004\">Repeatability Verification Procedure<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Perform the DTC Reading Procedure.<\/p>\n<p>(See <a href=\"SM352608\">ON-BOARD DIAGNOSTIC TEST [PCM (SKYACTIV-G 2.0)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Is the same DTC present?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repeat the inspection from Step 1.<\/p>\n<ul type=\"disc\">\n<li>\n<p>If the malfunction recurs, replace the PCM.<\/p>\n<p>(See <a href=\"SM352816\">PCM REMOVAL\/INSTALLATION [SKYACTIV-G 2.0]<\/a>.)<\/p>\n<\/li>\n<\/ul>\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>10<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>PURPOSE: VERIFY IF THERE IS ANY OTHER MALFUNCTION<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Is any other DTC or pending code stored?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the applicable DTC inspection.<\/p>\n<p>(See <a href=\"SM352613\">DTC TABLE [PCM (SKYACTIV-G 2.0)]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>DTC troubleshooting completed.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a class=\"prevPage\" href=\"SM352593\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM352595\">Next &gt;<\/a><\/p>\n<div align=\"right\">\n            <a href=\"\"#\">Back to Top<\/a>\n          <\/div>\n<div align=\"center\">\n            <em>\u00a9 2014 Mazda North American Operations, U.S.A.<\/em>\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&lt; Previous Next &gt; 2016 &#8211; MX-5 &#8211; Engine DTC P2504:00 [PCM (SKYACTIV-G 2.0)] NOTE: To determine the malfunctioning part, proceed with the diagnostics from &#8220;Function Inspection Using M-MDS&#8221;. Details On DTCs DESCRIPTION Generator system: Voltage generated by generator is high DETECTION CONDITION Determination conditions The voltage generated by the generator is 18.5 V or higher or the battery voltage is 16 V or higher for a continuous specified time. Preconditions While engine is running [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-8927","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/8927","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/comments?post=8927"}],"version-history":[{"count":0,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/8927\/revisions"}],"wp:attachment":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/media?parent=8927"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}