{"id":9603,"date":"2017-06-11T23:57:42","date_gmt":"2017-06-11T23:57:42","guid":{"rendered":"http:\/\/mazdaman.x10host.com\/sm353276\/"},"modified":"2017-06-11T23:57:42","modified_gmt":"2017-06-11T23:57:42","slug":"sm353276","status":"publish","type":"page","link":"https:\/\/chroot-me.in\/16ND\/sm353276\/","title":{"rendered":"DTC U200D:11 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]"},"content":{"rendered":"<div class=\"node node SERVICE_MANUALS\">\n    <\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT c1\">\n<div class=\"content\">\n          <link rel=\"stylesheet\" type=\"text\/css\" href=\"style.css\" media=\"screen\"><a class=\"prevPage\" href=\"SM353275\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353277\">Next &gt;<\/a><\/p>\n<h2>2016 &#8211; MX-5 &#8211; HVAC<\/h2>\n<p><a name=\"id0702k3736600\" id=\"id0702k3736600\"><\/a><\/p>\n<h3>DTC U200D:11 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]<\/h3>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>System malfunction location<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Climate control unit circuit voltage (+5V) circuit short to ground<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Detection condition<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Malfunction in wiring harness between climate control unit circuit voltage (+5V) and each sensor\/actuator<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Fail-safe function<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Not applicable<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Possible cause<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Connector or terminal malfunction<\/p>\n<\/li>\n<li>\n<p>Each actuator malfunction<\/p>\n<\/li>\n<li>\n<p>Short to ground in wiring harness between climate control unit and air mix actuator<\/p>\n<\/li>\n<li>\n<p>Short to ground in wiring harness between climate control unit and airflow mode actuator<\/p>\n<\/li>\n<li>\n<p>Climate control unit malfunction<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p align=\"center\"><a href=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUW00004198.GIF\"><img decoding=\"async\" align=\"absmiddle\" border=\"0\" src=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUW00004198.GIF\"><\/a><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a name=\"id0702k373660001\" id=\"id0702k373660001\"><\/a><\/p>\n<h4>Diagnostic procedure<\/h4>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>STEP<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p>INSPECTION<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>ACTION<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>1<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY CLIMATE CONTROL UNIT CONNECTOR CONDITION<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Switch the ignition off.<\/p>\n<\/li>\n<li>\n<p>Disconnect the negative battery cable.<\/p>\n<p>(See <a href=\"SM352783\">NEGATIVE BATTERY CABLE DISCONNECTION\/CONNECTION<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Disconnect the climate control unit connectors.<\/p>\n<p>(See <a href=\"SM353361\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Inspect the connector and terminals (corrosion, damage, pin disconnection).<\/p>\n<\/li>\n<li>\n<p>Are the connector and terminals normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair\/replace the malfunctioning vehicle wiring harness, connector, or terminal.<\/p>\n<p>After repair procedure, go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>2<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY CONNECTOR CONDITION<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the following each sensor\/actuator connectors.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Air mix actuator<\/p>\n<p>(See <a href=\"SM353356\">AIR MIX ACTUATOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Airflow mode actuator<\/p>\n<p>(See <a href=\"SM353353\">AIRFLOW MODE ACTUATOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Inspect the connector and terminals (corrosion, damage, pin disconnection).<\/p>\n<\/li>\n<li>\n<p>Are the connector and terminals normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the malfunctioning part.<\/p>\n<p>(See <a href=\"SM353356\">AIR MIX ACTUATOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353353\">AIRFLOW MODE ACTUATOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<p>After replace procedure, go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>3<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT EACH SENSOR\/ACTUATOR<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect the following each sensor\/actuator.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Air mix actuator<\/p>\n<p>(See <a href=\"SM353357\">AIR MIX ACTUATOR INSPECTION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Airflow mode actuator<\/p>\n<p>(See <a href=\"SM353354\">AIRFLOW MODE ACTUATOR INSPECTION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is it normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the malfunctioning sensor\/actuator.<\/p>\n<p>(See <a href=\"SM353356\">AIR MIX ACTUATOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353353\">AIRFLOW MODE ACTUATOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<p>After replace procedure, go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>4<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT EACH SENSOR\/ACTUATOR CIRCUIT FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect for continuity between the following terminal (wiring harness-side) and body ground:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Climate control unit terminal H<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal H and each sensor\/actuator terminals.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness which has a short to ground.<\/p>\n<\/li>\n<\/ul>\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>5<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY THAT SAME DTC IS NOT OUTPUT AGAIN<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Reconnect the disconnected connectors.<\/p>\n<\/li>\n<li>\n<p>Connect the negative battery cable.<\/p>\n<p>(See <a href=\"SM352783\">NEGATIVE BATTERY CABLE DISCONNECTION\/CONNECTION<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Clear the past malfunction from memory.<\/p>\n<p>(See <a href=\"SM353279\">CLEARING DTC [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Verify DTCs.<\/p>\n<p>(See <a href=\"SM353278\">DTC DISPLAY [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Is DTC U200D:11 output?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repeat the inspection from Step 1.<\/p>\n<ul type=\"disc\">\n<li>\n<p>If the malfunction does not recur, go to the next step.<\/p>\n<\/li>\n<li>\n<p>If the malfunction recurs, replace the climate control unit.<\/p>\n<p>(See <a href=\"SM353361\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<\/ul>\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>6<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY THAT NO OTHER DTCs ARE PRESENT<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Verify other DTCs displayed.<\/p>\n<p>(See <a href=\"SM353278\">DTC DISPLAY [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Are any other DTCs output?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Perform the corresponding DTC inspection.<\/p>\n<p>(See <a href=\"SM353280\">DTC TABLE [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>DTC troubleshooting completed.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a class=\"prevPage\" href=\"SM353275\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353277\">Next &gt;<\/a><\/p>\n<div align=\"right\">\n            <a href=\"\"#\">Back to Top<\/a>\n          <\/div>\n<div align=\"center\">\n            <em>\u00a9 2014 Mazda North American Operations, U.S.A.<\/em>\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&lt; Previous Next &gt; 2016 &#8211; MX-5 &#8211; HVAC DTC U200D:11 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] System malfunction location Climate control unit circuit voltage (+5V) circuit short to ground Detection condition Malfunction in wiring harness between climate control unit circuit voltage (+5V) and each sensor\/actuator Fail-safe function Not applicable Possible cause Connector or terminal malfunction Each actuator malfunction Short to ground in wiring harness between climate control unit and air mix actuator Short to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-9603","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9603","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/comments?post=9603"}],"version-history":[{"count":0,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9603\/revisions"}],"wp:attachment":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/media?parent=9603"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}