{"id":9604,"date":"2017-06-11T23:57:42","date_gmt":"2017-06-11T23:57:42","guid":{"rendered":"http:\/\/mazdaman.x10host.com\/sm353277\/"},"modified":"2017-06-11T23:57:42","modified_gmt":"2017-06-11T23:57:42","slug":"sm353277","status":"publish","type":"page","link":"https:\/\/chroot-me.in\/16ND\/sm353277\/","title":{"rendered":"DTC U2300:54, U2300:55, U2300:56, U2300:64 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]"},"content":{"rendered":"<div class=\"node node SERVICE_MANUALS\">\n    <\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT c2\">\n<div class=\"content\">\n          <link rel=\"stylesheet\" type=\"text\/css\" href=\"style.css\" media=\"screen\"><a class=\"prevPage\" href=\"SM353276\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353278\">Next &gt;<\/a><\/p>\n<h2>2016 &#8211; MX-5 &#8211; HVAC<\/h2>\n<p><a name=\"id0702k3745500\" id=\"id0702k3745500\"><\/a><\/p>\n<h3>DTC U2300:54, U2300:55, U2300:56, U2300:64 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]<\/h3>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>System malfunction location<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>U2300:54: Configuration error (data not received)<\/p>\n<\/li>\n<li>\n<p>U2300:55: Configuration error (not configured)<\/p>\n<\/li>\n<li>\n<p>U2300:56: Configuration error (ineffective\/non-interchangeable data read)<\/p>\n<\/li>\n<li>\n<p>U2300:64: Configuration error (error value read)<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Detection condition<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Climate control unit detects configuration data not record or data error<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Fail-safe function<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Sets the configuration value to the fixed value<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Possible cause<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b><span class=\"c1\">NOTE:<\/span><\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>If power from the battery is interrupted, the climate control unit will go into a non-configured state because the memory for the configuration information is erased.<\/p>\n<\/li>\n<li>\n<p>Normally, the configuration is re-performed within <b>6 s<\/b> after the ignition is switched ON (engine off).<\/p>\n<\/li>\n<li>\n<p>After performing the configuration, DTC U2300:55 will be cleared if the ignition is switched ON (engine off) after the ignition is switched off.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Module configuration procedure was not completed properly<\/p>\n<\/li>\n<li>\n<p>Correct data cannot be received from instrument cluster<\/p>\n<\/li>\n<li>\n<p>Climate control unit malfunction<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>System wiring diagram<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Not applicable<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a name=\"id0702k374550001\" id=\"id0702k374550001\"><\/a><\/p>\n<h4>Diagnostic Procedure<\/h4>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Step<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p>Inspection<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Action<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>1<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n                  <b>RECORD CAR CONFIGURATION DATA<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Switch the ignition ON (engine off) and wait for <b>6 s or more<\/b>.<\/p>\n<\/li>\n<li>\n<p>Switch the ignition off.<\/p>\n<\/li>\n<li>\n<p>Switch the ignition ON (engine off).<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>2<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY THAT SAME DTC IS NOT PRESENT<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Clear the DTCs from the memory.<\/p>\n<p>(See <a href=\"SM353279\">CLEARING DTC [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Perform the climate control unit DTC inspection using the M-MDS.<\/p>\n<p>(See <a href=\"SM353278\">DTC DISPLAY [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Are the same DTCs present?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repeat the inspection from Step 1.<\/p>\n<p>If the malfunction recurs, go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 5.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>3<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR INSTRUMENT CLUSTER MALFUNCTION<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Switch the ignition off.<\/p>\n<\/li>\n<li>\n<p>Perform the instrument cluster DTC inspection using the M-MDS.<\/p>\n<p>(See <a href=\"SM355717\">DTC INSPECTION [INSTRUMENT CLUSTER]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Are any DTCs present?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to applicable DTC inspection.<\/p>\n<p>(See <a href=\"SM355719\">DTC TABLE [INSTRUMENT CLUSTER]<\/a>.)<\/p>\n<p>After repairing the instrument cluster, perform the instrument cluster configuration.<\/p>\n<p>(See <a href=\"SM356365\">INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA)<\/a>.)<\/p>\n<p>Then go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>4<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY THAT SAME DTC IS NOT PRESENT<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Clear the DTCs from the memory.<\/p>\n<p>(See <a href=\"SM353279\">CLEARING DTC [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Perform the climate control unit DTC inspection using the M-MDS.<\/p>\n<p>(See <a href=\"SM353278\">DTC DISPLAY [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Are the same DTCs present?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repeat the inspection from Step 1.<\/p>\n<ul type=\"disc\">\n<li>\n<p>If the malfunction does not recur, go to the next step.<\/p>\n<\/li>\n<li>\n<p>If the malfunction recurs, replace the climate control unit.<\/p>\n<p>(See <a href=\"SM353361\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<\/ul>\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>5<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY THAT NO OTHER DTCs ARE PRESENT<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Verify other DTCs displayed.<\/p>\n<p>(See <a href=\"SM353278\">DTC DISPLAY [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Are any other DTCs output?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Perform the corresponding DTC inspection.<\/p>\n<p>(See <a href=\"SM353259\">DTC TABLE [CLIMATE CONTROL UNIT (FULL-AUTO AIR CONDITIONER)]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>DTC troubleshooting completed.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a class=\"prevPage\" href=\"SM353276\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353278\">Next &gt;<\/a><\/p>\n<div align=\"right\">\n            <a href=\"\"#\">Back to Top<\/a>\n          <\/div>\n<div align=\"center\">\n            <em>\u00a9 2014 Mazda North American Operations, U.S.A.<\/em>\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&lt; Previous Next &gt; 2016 &#8211; MX-5 &#8211; HVAC DTC U2300:54, U2300:55, U2300:56, U2300:64 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)] System malfunction location U2300:54: Configuration error (data not received) U2300:55: Configuration error (not configured) U2300:56: Configuration error (ineffective\/non-interchangeable data read) U2300:64: Configuration error (error value read) Detection condition Climate control unit detects configuration data not record or data error Fail-safe function Sets the configuration value to the fixed value Possible cause NOTE: If power from [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-9604","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9604","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/comments?post=9604"}],"version-history":[{"count":0,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9604\/revisions"}],"wp:attachment":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/media?parent=9604"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}