{"id":9618,"date":"2017-06-11T23:57:41","date_gmt":"2017-06-11T23:57:41","guid":{"rendered":"http:\/\/mazdaman.x10host.com\/sm353291\/"},"modified":"2017-06-11T23:57:41","modified_gmt":"2017-06-11T23:57:41","slug":"sm353291","status":"publish","type":"page","link":"https:\/\/chroot-me.in\/16ND\/sm353291\/","title":{"rendered":"AIR INTAKE MODE DOES NOT CHANGE [CLIMATE CONTROL SYSTEM]"},"content":{"rendered":"<div class=\"node node SERVICE_MANUALS\">\n    <\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT c1\">\n<div class=\"content\">\n          <link rel=\"stylesheet\" type=\"text\/css\" href=\"style.css\" media=\"screen\"><a class=\"prevPage\" href=\"SM353290\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353292\">Next &gt;<\/a><\/p>\n<h2>2016 &#8211; MX-5 &#8211; HVAC<\/h2>\n<p><a name=\"id0703k2700500\" id=\"id0703k2700500\"><\/a><\/p>\n<h3>AIR INTAKE MODE DOES NOT CHANGE [CLIMATE CONTROL SYSTEM]<\/h3>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>DESCRIPTION<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Air intake mode does not change when switching REC\/FRESH mode<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>POSSIBLE CAUSE<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Air intake actuator malfunction<\/p>\n<\/li>\n<li>\n<p>Open or short circuit in wiring harness between climate control unit and air intake actuator<\/p>\n<\/li>\n<li>\n<p>Climate control unit malfunction<\/p>\n<\/li>\n<li>\n<p>Air intake link malfunction<\/p>\n<\/li>\n<li>\n<p>Air intake door malfunction<\/p>\n<\/li>\n<li>\n<p>Restriction in A\/C unit<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>\n<ul type=\"disc\">\n<li>\n<p>When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, inspect to make sure connectors, terminals and wiring harnesses are connected correctly and undamaged.<\/p>\n<\/li>\n<\/ul>\n<p>          <a name=\"id0703k270050001\" id=\"id0703k270050001\"><\/a><\/p>\n<h4>Diagnostic Procedure<\/h4>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Step<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p>Inspection<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Action<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>1<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT AIR INTAKE ACTUATOR<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect the following item using the M-MDS A\/C operation check mode function.<\/p>\n<p>(See <a href=\"SM353267\">A\/C OPERATION CHECK MODE [CLIMATE CONTROL UNIT (FULL-AUTO AIR CONDITIONER)]<\/a>.)<\/p>\n<p>(See <a href=\"SM353287\">A\/C OPERATION CHECK MODE [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]<\/a>.)<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Air Intake Actuator<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Does the air intake actuator operate?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 7.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>2<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION IS IN AIR INTAKE ACTUATOR OR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the air intake actuator connector.<\/p>\n<\/li>\n<li>\n<p>Switch the ignition ON (engine off or on).<\/p>\n<p>(See <a href=\"SM353333\">AIR INTAKE ACTUATOR REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353351\">AIR INTAKE ACTUATOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Measure the voltages at the following climate control unit terminals.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal U (FRESH motor drive signal)<\/p>\n<\/li>\n<li>\n<p>Terminal S (RECIRCULATE motor drive signal)<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Are voltages normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 4.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>3<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT AIR INTAKE ACTUATOR<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect the air intake actuator.<\/p>\n<p>(See <a href=\"SM353334\">AIR INTAKE ACTUATOR INSPECTION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353352\">AIR INTAKE ACTUATOR INSPECTION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Is the air intake actuator normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 7.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the air intake actuator.<\/p>\n<p>(See <a href=\"SM353333\">AIR INTAKE ACTUATOR REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353351\">AIR INTAKE ACTUATOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<p>Then go to Step 9.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>4<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO B+ BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Air intake actuator connector disconnected.<\/p>\n<\/li>\n<li>\n<p>Disconnect the climate control unit connector.<\/p>\n<p>(See <a href=\"SM353347\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353361\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Measure the voltages at the following air intake actuator terminals.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal A (FRESH motor drive signal)<\/p>\n<\/li>\n<li>\n<p>Terminal B (RECIRCULATE motor drive signal)<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Are voltages <b>approx. 0 V<\/b>?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air intake actuator terminal.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness which has a short to power supply.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 9.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>5<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO GROUND BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Climate control unit and air intake actuator connectors disconnected.<\/p>\n<\/li>\n<li>\n<p>Switch the ignition off.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals between the air intake actuator and ground.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal A (FRESH motor drive signal)<\/p>\n<\/li>\n<li>\n<p>Terminal B (RECIRCULATE motor drive signal)<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air intake actuator terminal.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness which has a short to ground.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 9.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>6<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY OR OPEN BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Climate control unit and air intake actuator connectors disconnected.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals between the air intake actuator and climate control unit.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal A\u2014U (FRESH motor drive signal)<\/p>\n<\/li>\n<li>\n<p>Terminal B\u2014S(RECIRCULATE motor drive signal)<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the climate control unit, then go to Step 9.<\/p>\n<p>(See <a href=\"SM353347\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353361\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air intake actuator terminal.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 9.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>7<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT AIR INTAKE LINK<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect the air intake link.<\/p>\n<p>(See <a href=\"SM353317\">A\/C UNIT REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Is there grease on link?<\/p>\n<\/li>\n<li>\n<p>Are the links securely and properly installed?<\/p>\n<\/li>\n<li>\n<p>Are the links free of obstructions and hindrances?<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Are the above items normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Apply grease to the links. If any the links are damaged, replace the air intake actuator, then go to Step 9.<\/p>\n<p>(See <a href=\"SM353318\">A\/C UNIT DISASSEMBLY\/ASSEMBLY<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>8<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR AIR INTAKE DOOR<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect the A\/C unit air intake door.<\/p>\n<p>(See <a href=\"SM353317\">A\/C UNIT REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Is the door free of obstructions, cracks, and damage?<\/p>\n<\/li>\n<li>\n<p>Are the doors securely and properly installed?<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Are the above items normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Remove obstruction, or install the doors in the proper position. If any doors are cracked or damaged, replace them, then go to the next step.<\/p>\n<p>(See <a href=\"SM353318\">A\/C UNIT DISASSEMBLY\/ASSEMBLY<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>9<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Does the air intake mode change smoothly?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Troubleshooting completed. Explain repairs to customer.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a class=\"prevPage\" href=\"SM353290\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353292\">Next &gt;<\/a><\/p>\n<div align=\"right\">\n            <a href=\"\"#\">Back to Top<\/a>\n          <\/div>\n<div align=\"center\">\n            <em>\u00a9 2014 Mazda North American Operations, U.S.A.<\/em>\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&lt; Previous Next &gt; 2016 &#8211; MX-5 &#8211; HVAC AIR INTAKE MODE DOES NOT CHANGE [CLIMATE CONTROL SYSTEM] DESCRIPTION Air intake mode does not change when switching REC\/FRESH mode POSSIBLE CAUSE Air intake actuator malfunction Open or short circuit in wiring harness between climate control unit and air intake actuator Climate control unit malfunction Air intake link malfunction Air intake door malfunction Restriction in A\/C unit When performing an asterisked (*) troubleshooting inspection, shake the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-9618","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9618","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/comments?post=9618"}],"version-history":[{"count":0,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9618\/revisions"}],"wp:attachment":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/media?parent=9618"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}