{"id":9619,"date":"2017-06-11T23:57:41","date_gmt":"2017-06-11T23:57:41","guid":{"rendered":"http:\/\/mazdaman.x10host.com\/sm353292\/"},"modified":"2017-06-11T23:57:41","modified_gmt":"2017-06-11T23:57:41","slug":"sm353292","status":"publish","type":"page","link":"https:\/\/chroot-me.in\/16ND\/sm353292\/","title":{"rendered":"NO TEMPERATURE CONTROL WITH CLIMATE CONTROL UNIT [CLIMATE CONTROL SYSTEM]"},"content":{"rendered":"<div class=\"node node SERVICE_MANUALS\">\n    <\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT c1\">\n<div class=\"content\">\n          <link rel=\"stylesheet\" type=\"text\/css\" href=\"style.css\" media=\"screen\"><a class=\"prevPage\" href=\"SM353291\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353293\">Next &gt;<\/a><\/p>\n<h2>2016 &#8211; MX-5 &#8211; HVAC<\/h2>\n<p><a name=\"id0703k2700600\" id=\"id0703k2700600\"><\/a><\/p>\n<h3>NO TEMPERATURE CONTROL WITH CLIMATE CONTROL UNIT [CLIMATE CONTROL SYSTEM]<\/h3>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>DESCRIPTION<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Temperature does not change when operating temperature dial<\/p>\n<\/li>\n<li>\n<p>Malfunction in A\/C unit and\/or climate control unit air mix system<\/p>\n<\/li>\n<li>\n<p>Malfunction in air mix actuator or related wiring harness<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>POSSIBLE CAUSE<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>INTERIOR 15 A fuse malfunction<\/p>\n<\/li>\n<li>\n<p>Open or short circuit in wiring harness between fuse block and climate control unit<\/p>\n<\/li>\n<li>\n<p>Open or short circuit in wiring harness between climate control unit and air mix actuator<\/p>\n<\/li>\n<li>\n<p>Air mix actuator malfunction<\/p>\n<\/li>\n<li>\n<p>Air mix gear malfunction<\/p>\n<\/li>\n<li>\n<p>Air mix door malfunction<\/p>\n<\/li>\n<li>\n<p>Climate control unit malfunction<\/p>\n<\/li>\n<li>\n<p>Heater hose malfunction<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>\n<ul type=\"disc\">\n<li>\n<p>When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions.<\/p>\n<p>If there is a problem, check to make sure connectors, terminals and wiring harnesses are connected correctly and undamaged.<\/p>\n<\/li>\n<\/ul>\n<p>          <a name=\"id0703k270060001\" id=\"id0703k270060001\"><\/a><\/p>\n<h4>Diagnostic Procedure<\/h4>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Step<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p>Inspection<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Action<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>1<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT COOLANT TEMPERATURE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Is the coolant sufficiently warmed up?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Warm up the engine, then go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>2*<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FUSE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Remove the INTERIOR 15 A fuse.<\/p>\n<\/li>\n<li>\n<p>Is the fuse normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>If the fuse is melted:<\/b><\/p>\n<p>Repair or replace wiring harness for short to ground and replace the fuse.<\/p>\n<p><b>If the fuse is deterioration:<\/b><\/p>\n<p>Replace the fuse.<\/p>\n<p>Then go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>3*<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION (OPEN CIRCUIT) IS IN B+ SIGNAL WIRING HARNESS (BETWEEN FUSE BLOCK AND CLIMATE CONTROL UNIT) OR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the climate control unit connector.<\/p>\n<p>(See <a href=\"SM353347\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353361\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Switch the ignition ON (engine off or on).<\/p>\n<\/li>\n<li>\n<p>Measure voltage at the following terminal of climate control unit.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal L<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is the voltage <b>approx. 12 V?<\/b><\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between fuse block terminal and climate control unit terminal.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness which has an open circuit.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>4*<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR AIR MIX ACTUATOR<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Switch the ignition off.<\/p>\n<\/li>\n<li>\n<p>Reconnect the disconnected climate control unit connector.<\/p>\n<\/li>\n<li>\n<p>Switch the ignition ON (engine off or on).<\/p>\n<\/li>\n<li>\n<p>Measure voltage at the following terminals of climate control unit when temperature setting to MAX HOT and MAX COLD.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal G<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is voltage normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 15.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>5*<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION IS IN POSITION SENSOR OR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Measure voltage at the following terminal of climate control unit when airflow mode at VENT and DEFROSTER.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal I<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is voltage normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 8.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>6*<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY OR SHORT TO BATTERY POWER OR GROUND) IS IN POSITION SENSOR POWER SUPPLY OR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Measure voltage at the following terminal of climate control unit.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal H<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is voltage <b>approx. 5 V?<\/b><\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>7*<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY OR OPEN) IS IN POSITION SENSOR GROUND OR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Measure voltage at the following terminal of climate control unit.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal E<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is the voltage <b>below. 1.0 V?<\/b><\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 11.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>8<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION (SHORT TO POWER SUPPLY) IS IN WIRING HARNESS (AIR MIX POSITION SIGNAL) OR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Measure voltage at the following terminals of climate control unit.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal G<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is the voltage <b>approx. 12V,<\/b> at Step 4?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness which has a short to power supply.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>9*<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN WIRING HARNESS (AIR MIX POSITION SIGNAL) OR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Switch the ignition off.<\/p>\n<\/li>\n<li>\n<p>Disconnect the climate control unit connector.<\/p>\n<p>(See <a href=\"SM353347\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353361\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Disconnect the air mix actuator connector.<\/p>\n<p>(See <a href=\"SM353338\">AIR MIX ACTUATOR REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353356\">AIR MIX ACTUATOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Verify continuity at following terminals between climate control unit and air mix actuator.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal G \u2014Terminal E<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and each side air mix actuator terminal.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>10*<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION (SHORT TO GROUND) IS IN WIRING HARNESS (AIR MIX POSITION SIGNAL) OR POSITION SENSOR COMMON (POWER SUPPLY OR GROUND) HARNESS<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Climate control unit and air mix actuator connectors disconnected.<\/p>\n<\/li>\n<li>\n<p>Verify continuity at the following terminals between climate control unit and ground.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal G<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair wiring harness for short to ground between climate control unit and air mix actuator.<\/p>\n<p>Then go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Inspect and repair for open circuit following:<\/p>\n<ul type=\"disc\">\n<li>\n<p>Between air mix actuator terminal D and junction point to airflow mode actuator (position sensor power supply).<\/p>\n<\/li>\n<li>\n<p>Between air mix actuator terminal F and junction point to airflow mode actuator (position sensor ground).<\/p>\n<\/li>\n<\/ul>\n<p>Then go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>11*<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION (LACK OF CONTINUITY) IS IN AIR MIX ACTUATOR OR WIRING HARNESS (BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR)<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the air mix actuator connector.<\/p>\n<p>(See <a href=\"SM353338\">AIR MIX ACTUATOR REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353356\">AIR MIX ACTUATOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Switch the ignition ON (engine off or on).<\/p>\n<\/li>\n<li>\n<p>Measure voltage at the following terminals of air mix actuator.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal W (COLD motor drive signal)<\/p>\n<\/li>\n<li>\n<p>Terminal X (HOT motor drive signal)<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Are voltages as shown below?<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>COLD motor drive signal: <b>approx. 10 V<\/b> during COLD and <b>below 1.0 V<\/b> during HOT<\/p>\n<\/li>\n<li>\n<p>HOT motor drive signal: <b>below 1.0 V<\/b> during COLD and <b>approx. 10 V<\/b> during HOT<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 15.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>12*<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO B+ BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Air mix actuator connectors disconnected.<\/p>\n<\/li>\n<li>\n<p>Disconnect the climate control unit connector.<\/p>\n<p>(See <a href=\"SM353347\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353361\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Switch the ignition ON (engine off or on).<\/p>\n<\/li>\n<li>\n<p>Measure voltage at the following terminals of the climate control unit harness-side connector.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal W (COLD motor drive signal)<\/p>\n<\/li>\n<li>\n<p>Terminal X (HOT motor drive signal)<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Are voltages <b>approx. 0 V?<\/b><\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness which has a short to power supply.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>13*<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO GROUND BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Climate control unit and air mix actuator connectors are disconnected.<\/p>\n<\/li>\n<li>\n<p>Switch the ignition off.<\/p>\n<\/li>\n<li>\n<p>Verify that continuity at the following harness-side connector terminals between climate control unit and ground.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Terminal W (COLD motor drive signal)<\/p>\n<\/li>\n<li>\n<p>Terminal X (HOT motor drive signal)<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness which has a short to ground.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>14*<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY OR OPEN BETWEEN CLIMATE CONTROL UNIT AND AIR MIX ACTUATOR) OR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Climate control unit and air mix actuator connectors are disconnected.<\/p>\n<\/li>\n<li>\n<p>Switch the ignition off.<\/p>\n<\/li>\n<li>\n<p>Verify that continuity at the following harness-side connector terminals between climate control unit and each air mix actuator.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Terminal A\u2014climate control unit terminal W (COLD motor drive signal)<\/p>\n<\/li>\n<li>\n<p>Terminal B\u2014climate control unit terminal X (HOT motor drive signal)<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air mix actuator terminal.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>15<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT AIR MIX ACTUATOR<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect the air mix actuator.<\/p>\n<p>(See <a href=\"SM353339\">AIR MIX ACTUATOR INSPECTION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353357\">AIR MIX ACTUATOR INSPECTION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Is air mix actuator normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the air mix actuator.<\/p>\n<p>Then go to 19.<\/p>\n<p>(See <a href=\"SM353338\">AIR MIX ACTUATOR REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353356\">AIR MIX ACTUATOR REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>16<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT AIR MIX GEAR<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect the air mix gears for each-side.<\/p>\n<p>(See <a href=\"SM353317\">A\/C UNIT REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Is grease on gear?<\/p>\n<\/li>\n<li>\n<p>Is gear securely and properly installed?<\/p>\n<\/li>\n<li>\n<p>Is gear free of obstructions and hindrances?<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Are the above items normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Apply grease to gear.<\/p>\n<p>If any gear is damaged. Replace malfunctioning part.<\/p>\n<p>(See <a href=\"SM353318\">A\/C UNIT DISASSEMBLY\/ASSEMBLY<\/a>.)<\/p>\n<p>Then go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>17<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR AIR MIX DOOR ELSEWHERE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect the A\/C unit and each-side air mix door.<\/p>\n<p>(See <a href=\"SM353317\">A\/C UNIT REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Is door free of obstructions and damage?<\/p>\n<\/li>\n<li>\n<p>Are doors securely and properly installed?<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Are the above items normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Remove the obstruction, or install door in proper position.<\/p>\n<p>If any door are cracked, replace them.<\/p>\n<p>(See <a href=\"SM353318\">A\/C UNIT DISASSEMBLY\/ASSEMBLY<\/a>.)<\/p>\n<p>Then go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>18<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT HEATER HOSE<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect the heater hoses for the following:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Is heater hoses free of damage and cracks?<\/p>\n<\/li>\n<li>\n<p>Are heater hoses connections free of engine coolant leakage?<\/p>\n<\/li>\n<li>\n<p>Are heater hoses installation points on A\/C unit free of engine coolant leakage?<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Are the above items normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the climate control unit.<\/p>\n<p>Then go to the next step.<\/p>\n<p>(See <a href=\"SM353347\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [FULL-AUTO AIR CONDITIONER]<\/a>.)<\/p>\n<p>(See <a href=\"SM353361\">CLIMATE CONTROL UNIT REMOVAL\/INSTALLATION [MANUAL AIR CONDITIONER]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>If heater hoses connections are loose, install securely in the correct position.<\/p>\n<p>Repair or replace the heater hoses.<\/p>\n<p>(See <a href=\"SM353329\">HEATER HOSE REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<p>Then go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>19<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY THAT MALFUNCTION SYMPTOM DOES NOT RECUR AFTER REPAIR<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Does the unit operate at every temperature setting?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Troubleshooting completed.<\/p>\n<p>Explain repairs to customer.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Recheck malfunction symptoms, then repeat from Step1 if the malfunction recurs.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a class=\"prevPage\" href=\"SM353291\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353293\">Next &gt;<\/a><\/p>\n<div align=\"right\">\n            <a href=\"\"#\">Back to Top<\/a>\n          <\/div>\n<div align=\"center\">\n            <em>\u00a9 2014 Mazda North American Operations, U.S.A.<\/em>\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&lt; Previous Next &gt; 2016 &#8211; MX-5 &#8211; HVAC NO TEMPERATURE CONTROL WITH CLIMATE CONTROL UNIT [CLIMATE CONTROL SYSTEM] DESCRIPTION Temperature does not change when operating temperature dial Malfunction in A\/C unit and\/or climate control unit air mix system Malfunction in air mix actuator or related wiring harness POSSIBLE CAUSE INTERIOR 15 A fuse malfunction Open or short circuit in wiring harness between fuse block and climate control unit Open or short circuit in wiring [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-9619","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9619","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/comments?post=9619"}],"version-history":[{"count":0,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9619\/revisions"}],"wp:attachment":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/media?parent=9619"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}