{"id":9750,"date":"2017-06-11T23:57:34","date_gmt":"2017-06-11T23:57:34","guid":{"rendered":"http:\/\/mazdaman.x10host.com\/sm353423\/"},"modified":"2017-06-11T23:57:34","modified_gmt":"2017-06-11T23:57:34","slug":"sm353423","status":"publish","type":"page","link":"https:\/\/chroot-me.in\/16ND\/sm353423\/","title":{"rendered":"DTC U2100:00 [SAS CONTROL MODULE (TWO-STEP DEPLOYMENT CONTROL SYSTEM)]"},"content":{"rendered":"<div class=\"node node SERVICE_MANUALS\">\n    <\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT c2\">\n<div class=\"content\">\n          <link rel=\"stylesheet\" type=\"text\/css\" href=\"style.css\" media=\"screen\"><a class=\"prevPage\" href=\"SM353422\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353424\">Next &gt;<\/a><\/p>\n<h2>2016 &#8211; MX-5 &#8211; Restraints<\/h2>\n<p><a name=\"id0802g8814100\" id=\"id0802g8814100\"><\/a><\/p>\n<h3>DTC U2100:00 [SAS CONTROL MODULE (TWO-STEP DEPLOYMENT CONTROL SYSTEM)]<\/h3>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>System malfunction location<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>U2100:00: Configuration not set<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Detection condition<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b><span class=\"c1\">WARNING:<\/span><\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Detection conditions are for understanding the DTC outline before performing an inspection. Performing an inspection according to only the detection conditions may cause injury due to an operating error, or damage the system. When performing an inspection, always follow the inspection procedure.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>SAS control module configuration setting has not been done correctly<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Fail-safe function<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Not applicable<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Possible cause<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>SAS control module configuration setting not implemented<\/p>\n<\/li>\n<li>\n<p>SAS control module malfunction<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>System wiring diagram<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Not applicable<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a name=\"id0802g881410001\" id=\"id0802g881410001\"><\/a><\/p>\n<h4>Diagnostic Procedure<\/h4>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Step<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p>Inspection<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Action<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>1<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY THAT NO OTHER DTCs ARE PRESENT<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Are any other DTCs output?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair the malfunction part according to the applicable DTC troubleshooting.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>2<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>PERFORM SAS CONTROL MODULE CONFIGURATION (AS-BUILT DATA USE)<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Perform the SAS control module configuration using the M-MDS.<\/p>\n<p>(See <a href=\"SM353479\">SAS CONTROL MODULE CONFIGURATION (USING AS-BUILT DATA) [TWO-STEP DEPLOYMENT CONTROL SYSTEM]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Clear the DTC for the SAS control module using the M-MDS.<\/p>\n<p>(See <a href=\"SM353415\">CLEARING DTC [SAS CONTROL MODULE (TWO-STEP DEPLOYMENT CONTROL SYSTEM)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Perform the DTC inspection for the SAS control module using the M-MDS.<\/p>\n<p>(See <a href=\"SM353414\">DTC INSPECTION [SAS CONTROL MODULE (TWO-STEP DEPLOYMENT CONTROL SYSTEM)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Are the same DTCs present?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>DTC troubleshooting completed.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>3<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>PERFORM SAS CONTROL MODULE DTC INSPECTION<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Clear the DTC for the SAS control module using the M-MDS.<\/p>\n<p>(See <a href=\"SM353415\">CLEARING DTC [SAS CONTROL MODULE (TWO-STEP DEPLOYMENT CONTROL SYSTEM)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Perform the DTC inspection for the SAS control module using the M-MDS.<\/p>\n<p>(See <a href=\"SM353414\">DTC INSPECTION [SAS CONTROL MODULE (TWO-STEP DEPLOYMENT CONTROL SYSTEM)]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Are the same DTCs present?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the SAS control module.<\/p>\n<p>(See <a href=\"SM353464\">SAS CONTROL MODULE REMOVAL\/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>DTC troubleshooting completed.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a class=\"prevPage\" href=\"SM353422\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353424\">Next &gt;<\/a><\/p>\n<div align=\"right\">\n            <a href=\"\"#\">Back to Top<\/a>\n          <\/div>\n<div align=\"center\">\n            <em>\u00a9 2014 Mazda North American Operations, U.S.A.<\/em>\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&lt; Previous Next &gt; 2016 &#8211; MX-5 &#8211; Restraints DTC U2100:00 [SAS CONTROL MODULE (TWO-STEP DEPLOYMENT CONTROL SYSTEM)] System malfunction location U2100:00: Configuration not set Detection condition WARNING: Detection conditions are for understanding the DTC outline before performing an inspection. Performing an inspection according to only the detection conditions may cause injury due to an operating error, or damage the system. When performing an inspection, always follow the inspection procedure. SAS control module configuration setting [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-9750","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9750","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/comments?post=9750"}],"version-history":[{"count":0,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9750\/revisions"}],"wp:attachment":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/media?parent=9750"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}