{"id":9885,"date":"2017-06-11T23:57:27","date_gmt":"2017-06-11T23:57:27","guid":{"rendered":"http:\/\/mazdaman.x10host.com\/sm353558\/"},"modified":"2017-06-11T23:57:27","modified_gmt":"2017-06-11T23:57:27","slug":"sm353558","status":"publish","type":"page","link":"https:\/\/chroot-me.in\/16ND\/sm353558\/","title":{"rendered":"DETERMINING SHORT TO GROUND LOCATION (HS-CAN)"},"content":{"rendered":"<div class=\"node node SERVICE_MANUALS\">\n    <\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT c2\">\n<div class=\"content\">\n          <link rel=\"stylesheet\" type=\"text\/css\" href=\"style.css\" media=\"screen\"><a class=\"prevPage\" href=\"SM353557\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353559\">Next &gt;<\/a><\/p>\n<h2>2016 &#8211; MX-5 &#8211; Multiplex Communication System<\/h2>\n<p><a name=\"id100200000600\" id=\"id100200000600\"><\/a><\/p>\n<h3>DETERMINING SHORT TO GROUND LOCATION (HS-CAN)<\/h3>\n<p><b><span class=\"c1\">CAUTION:<\/span><\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Perform the following malfunction diagnosis only when it is diagnosed with a short to ground by CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW. (See <a href=\"SM353553\">CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW<\/a>.)<\/p>\n<\/li>\n<\/ul>\n<p>          <a name=\"id10020000060001\" id=\"id10020000060001\"><\/a><\/p>\n<h4>System Wiring Diagram<\/h4>\n<p align=\"center\"><a href=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUW00004954.GIF\"><img decoding=\"async\" align=\"absmiddle\" border=\"0\" src=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUW00004954.GIF\"><\/a><\/p>\n<p><a name=\"id10020000060002\" id=\"id10020000060002\"><\/a><\/p>\n<h4>Determination Procedure<\/h4>\n<p><b><span class=\"c1\">CAUTION:<\/span><\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>When disconnecting the connector, verify that there is no looseness, damage, deformation, corrosion, or poor connection of the connector terminals.<\/p>\n<\/li>\n<li>\n<p>When inspecting the DLC-2, touch it with a paper clip or similar thin pin without directly inserting a tester into the terminals.<\/p>\n<\/li>\n<\/ul>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Step<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p>Inspection<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Action<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>1<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN BCM AND INSTRUMENT CLUSTER<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Switch the ignition off.<\/p>\n<\/li>\n<li>\n<p>Disconnect the negative battery cable.<\/p>\n<p>(See <a href=\"SM352783\">NEGATIVE BATTERY CABLE DISCONNECTION\/CONNECTION<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Disconnect the connector 2 and 3 which has BCM terminals 3C,3D and 2D,2C.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between DLC-2 terminal F and body ground<\/p>\n<\/li>\n<li>\n<p>Between DLC-2 terminal E and body ground<\/p>\n<\/li>\n<\/ul>\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 8.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>2<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN BCM FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between BCM terminal 3C and body ground<\/p>\n<\/li>\n<li>\n<p>Between BCM terminal 3D and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the BCM because there is a short to ground in the BCM.<\/p>\n<p>(See <a href=\"SM356376\">BODY CONTROL MODULE (BCM) REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>3<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN CONNECTORS C-38 AND C-39 AND BCM<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Connect the connector 2 and 3 which has BCM terminals 3C,3D and 2D,2C.<\/p>\n<\/li>\n<li>\n<p>Disconnect the connectors C-38 and C-39.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between DLC-2 terminal F and body ground<\/p>\n<\/li>\n<li>\n<p>Between DLC-2 terminal E and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the connectors C-38 and C-39 and BCM because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>4<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN DSC HU\/CM FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the DSC HU\/CM connector.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between DSC HU\/CM terminal C (wiring harness side) and body ground<\/p>\n<\/li>\n<li>\n<p>Between DSC HU\/CM terminal D (wiring harness side) and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the DSC HU\/CM because there is a short to ground in the DSC HU\/CM.<\/p>\n<p>(See <a href=\"SM353033\">DSC HU\/CM REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>5<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN EVP CONTROL UNIT FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the EVP control unit connector.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between EVP control unit terminal AD (wiring harness side) and body ground<\/p>\n<\/li>\n<li>\n<p>Between EVP control unit terminal Z (wiring harness side) and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the EVP control unit because there is a short to ground in the EVP control unit.<\/p>\n<p>(See <a href=\"SM352992\">EVP CONTROL UNIT REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>6<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN EPS CONTROL MODULE FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the EPS control module connector.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between EPS control module terminal 2B (wiring harness side) and body ground<\/p>\n<\/li>\n<li>\n<p>Between EPS control module terminal 2C (wiring harness side) and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the EPS control module because there is a short to ground in the EPS control module.<\/p>\n<p>(See <a href=\"SM353228\">STEERING WHEEL AND COLUMN REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>7<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN PCM FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the PCM connector.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between PCM terminal 2AK (wiring harness side) and body ground<\/p>\n<\/li>\n<li>\n<p>Between PCM terminal 2AL (wiring harness side) and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the PCM and connectors C-38 and C-39 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the PCM because there is a short to ground in the PCM.<\/p>\n<p>(See <a href=\"SM352816\">PCM REMOVAL\/INSTALLATION [SKYACTIV-G 2.0]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>8<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-42 AND INSTRUMENT CLUSTER<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the connector C-42.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between DLC-2 terminal F and body ground<\/p>\n<\/li>\n<li>\n<p>Between DLC-2 terminal E and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 12.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>9<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN AUDIO AMPLIFIER AND CONNECTOR C-42<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between audio amplifier terminal 2L and body ground<\/p>\n<\/li>\n<li>\n<p>Between audio amplifier terminal 2N and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 11.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>10<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN AUDIO AMPLIFIER FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the audio amplifier connector.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between audio amplifier terminal 2L (wiring harness side) and body ground<\/p>\n<\/li>\n<li>\n<p>Between audio amplifier terminal 2N (wiring harness side) and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the audio amplifier and connector C-42 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the audio amplifier because there is a short to ground in the audio amplifier.<\/p>\n<p>(See <a href=\"SM356313\">AUDIO AMPLIFIER REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>11<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN TCM FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the TCM connector.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between TCM terminal 2G (wiring harness side) and body ground<\/p>\n<\/li>\n<li>\n<p>Between TCM terminal 2C (wiring harness side) and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the TCM and connector C-42 and BCM because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the TCM because there is a short to ground in the TCM.<\/p>\n<p>(See <a href=\"SM353193\">CONTROL VALVE BODY REMOVAL [SJ6A-EL]<\/a>.)<\/p>\n<p>(See <a href=\"SM353194\">CONTROL VALVE BODY INSTALLATION [SJ6A-EL]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>12<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-25 AND INSTRUMENT CLUSTER<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the connector C-25.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between DLC-2 terminal F and body ground<\/p>\n<\/li>\n<li>\n<p>Between DLC-2 terminal E and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 15.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>13<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-30 AND CONNECTOR C-42 AND CONNECTOR C-25<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the connector C-30.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between occupant classification sensor terminal 4B and body ground<\/p>\n<\/li>\n<li>\n<p>Between occupant classification sensor terminal 4A and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the connector C-30 and connector C-42 and connector C-25 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>14<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN OCCUPANT CLASSIFICATION SENSOR FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the occupant classification sensor connector.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between occupant classification sensor terminal 4B (wiring harness side) and body ground<\/p>\n<\/li>\n<li>\n<p>Between occupant classification sensor terminal 4A (wiring harness side) and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the occupant classification sensor and connector C-30 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the occupant classification sensor because there is a short to ground in the occupant classification sensor.<\/p>\n<p>(See <a href=\"SM353472\">OCCUPANT CLASSIFICATION SENSOR REMOVAL\/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>15<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-14 AND INSTRUMENT CLUSTER<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the connector C-14.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between DLC-2 terminal F and body ground<\/p>\n<\/li>\n<li>\n<p>Between DLC-2 terminal E and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the connector C-25 and connector C-14 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>16<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-17 AND INSTRUMENT CLUSTER<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the connector C-17.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between DLC-2 terminal F and body ground<\/p>\n<\/li>\n<li>\n<p>Between DLC-2 terminal E and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 19.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>17<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN FORWARD SENSING CAMERA (FSC) AND CONNECTOR C-17<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between forward sensing camera (FSC) terminal E and body ground<\/p>\n<\/li>\n<li>\n<p>Between forward sensing camera (FSC) terminal C and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the connector C-14 and connector C-17 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>18<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN FORWARD SENSING CAMERA (FSC) FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the forward sensing camera (FSC) connector.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between forward sensing camera (FSC) terminal E (wiring harness side) and body ground<\/p>\n<\/li>\n<li>\n<p>Between forward sensing camera (FSC) terminal C (wiring harness side) and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the forward sensing camera (FSC) and connector C-17 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the forward sensing camera (FSC) because there is a short to ground in the forward sensing camera (FSC).<\/p>\n<p>(See <a href=\"SM353670\">FORWARD SENSING CAMERA (FSC) REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>19<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-41 AND DLC-2<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the connector C-41.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between DLC-2 terminal F and body ground<\/p>\n<\/li>\n<li>\n<p>Between DLC-2 terminal E and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the connector C-41 and DLC-2 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>20<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN AFS CONTROL MODULE \/ AUTO LEVELING CONTROL MODULE AND CONNECTOR C-17 AND CONNECTOR C-41<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between AFS control module \/ auto leveling control module terminal A and body ground<\/p>\n<\/li>\n<li>\n<p>Between AFS control module \/ auto leveling control module terminal B and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 22.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>21<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN AFS CONTROL MODULE \/ AUTO LEVELING CONTROL MODULE FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the AFS control module \/ auto leveling control module connector.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between AFS control module \/ auto leveling control module terminal A (wiring harness side) and body ground<\/p>\n<\/li>\n<li>\n<p>Between AFS control module \/ auto leveling control module terminal B (wiring harness side) and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the AFS control module \/ auto leveling control module and connector C-17 and connector C-41 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the AFS control module \/ auto leveling control module because there is a short to ground in the AFS control module \/ auto leveling control module.<\/p>\n<p>(See <a href=\"SM356256\">AUTO LEVELING CONTROL MODULE REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<p>(See <a href=\"SM353669\">ADAPTIVE FRONT LIGHTING SYSTEM (AFS) CONTROL MODULE REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>22<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN START STOP UNIT AND CONNECTOR C-41<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between start stop unit terminal 2M and body ground<\/p>\n<\/li>\n<li>\n<p>Between start stop unit terminal 2O and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 25.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>23<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN START STOP UNIT AND CONNECTOR C-19<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the connector C-19.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between start stop unit terminal 2M and body ground<\/p>\n<\/li>\n<li>\n<p>Between start stop unit terminal 2O and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the connector C-19 and connector C-41 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>24<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN START STOP UNIT FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the start stop unit connector.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between start stop unit terminal 2M (wiring harness side) and body ground<\/p>\n<\/li>\n<li>\n<p>Between start stop unit terminal 2O (wiring harness side) and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the start stop unit and connector C-19 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the start stop unit because there is a short to ground in the start stop unit.<\/p>\n<p>(See <a href=\"SM356095\">START STOP UNIT REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>25<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN CONNECTIVITY MASTER UNIT (CMU) AND CONNECTOR C-41<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between connectivity master unit (CMU) terminal 2E and body ground<\/p>\n<\/li>\n<li>\n<p>Between connectivity master unit (CMU) terminal 2F and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 27.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>26<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN CONNECTIVITY MASTER UNIT (CMU) FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the connectivity master unit (CMU) connector.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between connectivity master unit (CMU) terminal 2E (wiring harness side) and body ground<\/p>\n<\/li>\n<li>\n<p>Between connectivity master unit (CMU) terminal 2F (wiring harness side) and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the connectivity master unit (CMU) and connector C-41 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the connectivity master unit (CMU) because there is a short to ground in the connectivity master unit (CMU).<\/p>\n<p>(See <a href=\"SM356302\">CONNECTIVITY MASTER UNIT (CMU) REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>27<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT FOR SHORT TO GROUND BETWEEN SAS CONTROL MODULE AND CONNECTOR C-41<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between SAS control module terminal 3Q and body ground<\/p>\n<\/li>\n<li>\n<p>Between SAS control module terminal 3S and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to Step 29.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>28<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN SAS CONTROL MODULE FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the SAS control module connector.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between SAS control module terminal 3Q (wiring harness side) and body ground<\/p>\n<\/li>\n<li>\n<p>Between SAS control module terminal 3S (wiring harness side) and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the SAS control module and connector C-41 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the SAS control module because there is a short to ground in the SAS control module.<\/p>\n<p>(See <a href=\"SM353464\">SAS CONTROL MODULE REMOVAL\/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM]<\/a>.)<\/p>\n<p>(See <a href=\"SM353486\">SAS CONTROL MODULE REMOVAL\/INSTALLATION [STANDARD DEPLOYMENT CONTROL SYSTEM]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>29<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT CAN LINE IN INSTRUMENT CLUSTER FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the instrument cluster connector.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity at the following terminals:<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>Between instrument cluster terminal B (wiring harness side) and body ground<\/p>\n<\/li>\n<li>\n<p>Between instrument cluster terminal D (wiring harness side) and body ground<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<ul type=\"disc\">\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the wiring harness between the instrument cluster and connector C-41 because the wiring harness is shorted to ground.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the instrument cluster because there is a short to ground in the instrument cluster.<\/p>\n<p>(See <a href=\"SM356358\">INSTRUMENT CLUSTER REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a class=\"prevPage\" href=\"SM353557\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353559\">Next &gt;<\/a><\/p>\n<div align=\"right\">\n            <a href=\"\"#\">Back to Top<\/a>\n          <\/div>\n<div align=\"center\">\n            <em>\u00a9 2014 Mazda North American Operations, U.S.A.<\/em>\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&lt; Previous Next &gt; 2016 &#8211; MX-5 &#8211; Multiplex Communication System DETERMINING SHORT TO GROUND LOCATION (HS-CAN) CAUTION: Perform the following malfunction diagnosis only when it is diagnosed with a short to ground by CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW. (See CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW.) System Wiring Diagram Determination Procedure CAUTION: When disconnecting the connector, verify that there is no looseness, damage, deformation, corrosion, or poor connection of the connector terminals. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-9885","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9885","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/comments?post=9885"}],"version-history":[{"count":0,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9885\/revisions"}],"wp:attachment":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/media?parent=9885"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}