{"id":9920,"date":"2017-06-11T23:57:24","date_gmt":"2017-06-11T23:57:24","guid":{"rendered":"http:\/\/mazdaman.x10host.com\/sm353593\/"},"modified":"2017-06-11T23:57:24","modified_gmt":"2017-06-11T23:57:24","slug":"sm353593","status":"publish","type":"page","link":"https:\/\/chroot-me.in\/16ND\/sm353593\/","title":{"rendered":"DTC B11CB:11 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]"},"content":{"rendered":"<div class=\"node node SERVICE_MANUALS\">\n    <\/p>\n<div class=\"textleft\">\n<div class=\"attr CONTENT c2\">\n<div class=\"content\">\n          <link rel=\"stylesheet\" type=\"text\/css\" href=\"style.css\" media=\"screen\"><a class=\"prevPage\" href=\"SM353592\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353594\">Next &gt;<\/a><\/p>\n<h2>2016 &#8211; MX-5 &#8211; i-ACTIVSENSE<\/h2>\n<p><a name=\"id1502b5013300\" id=\"id1502b5013300\"><\/a><\/p>\n<h3>DTC B11CB:11 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]<\/h3>\n<p><b><span class=\"c1\">CAUTION:<\/span><\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>When replacing a blind spot monitoring (BSM) control module (RH) having any of the following part numbers, it is necessary to replace the blind spot monitoring (BSM) control module (LH) at the same time to perform the configuration normally.<\/p>\n<\/li>\n<ul type=\"square\">\n<li>\n<p>N243-67Y80 A<\/p>\n<\/li>\n<li>\n<p>N243-67Y80 B<\/p>\n<\/li>\n<li>\n<p>N243-67Y80 C<\/p>\n<\/li>\n<\/ul>\n<\/ul>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Description<\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Blind spot monitoring (BSM) warning light (RH) circuit malfunction<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Detection condition<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Blind spot monitoring (BSM) control module (RH) detects a short to ground in the blind spot monitoring (BSM) warning light (RH) circuit with the ignition switched ON (engine off or on).<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Fail-safe<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Blind spot monitoring (BSM) system is stopped.<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p><b>Possible cause<\/b><\/p>\n<\/td>\n<td valign=\"middle\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<ul type=\"disc\">\n<li>\n<p>Blind spot monitoring (BSM) warning light (RH) connector or terminal malfunction<\/p>\n<\/li>\n<li>\n<p>Blind spot monitoring (BSM) control module (RH) connector or terminal malfunction<\/p>\n<\/li>\n<li>\n<p>Short to ground in wiring harness between blind spot monitoring (BSM) control module (RH) terminal D and blind spot monitoring (BSM) warning light (RH) terminal D<\/p>\n<\/li>\n<li>\n<p>Blind spot monitoring (BSM) warning light (RH) malfunction<\/p>\n<\/li>\n<li>\n<p>Blind spot monitoring (BSM) control module (RH) malfunction<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p align=\"center\"><a href=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUW00004520.GIF\"><img decoding=\"async\" align=\"absmiddle\" border=\"0\" src=\"\/16ND\/wp-content\/uploads\/2017\/05\/AMXUUW00004520.GIF\"><\/a><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <b>Diagnostic Procedure<\/b><\/p>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"@colsep\" bordercolor=\"#CCCCCC\" frame=\"box\" rules=\"all\">\n<tbody valign=\"\" cellspacing=\"1\" rowspan=\"\">\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Step<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"2\">\n<p>Inspection<\/p>\n<\/td>\n<td valign=\"middle\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Action<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>1<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT BLIND SPOT MONITORING (BSM) WARNING LIGHT (RH) CONNECTOR CONDITION<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Switch the ignition off.<\/p>\n<\/li>\n<li>\n<p>Disconnect the negative battery cable.<\/p>\n<p>(See <a href=\"SM352783\">NEGATIVE BATTERY CABLE DISCONNECTION\/CONNECTION<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Disconnect the blind spot monitoring (BSM) warning light (RH) connector.<\/p>\n<\/li>\n<li>\n<p>Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.<\/p>\n<\/li>\n<li>\n<p>Is the connector normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the connector, then go to Step 5.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>2<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT BLIND SPOT MONITORING (BSM) CONTROL MODULE (RH) CONNECTOR CONDITION<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Disconnect the blind spot monitoring (BSM) control module (RH) connector.<\/p>\n<\/li>\n<li>\n<p>Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.<\/p>\n<\/li>\n<li>\n<p>Is the connector normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the connector, then go to Step 5.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>3<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT BLIND SPOT MONITORING (BSM) WARNING LIGHT (RH) CIRCUIT FOR SHORT TO GROUND<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Verify that the blind spot monitoring (BSM) control module (RH) and blind spot monitoring (BSM) warning light (RH) connectors are disconnected.<\/p>\n<\/li>\n<li>\n<p>Inspect for continuity between blind spot monitoring (BSM) warning light (RH) terminal D (wiring harness-side) and body ground.<\/p>\n<\/li>\n<li>\n<p>Is there continuity?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Refer to the wiring diagram and verify whether or not there is a common connector between blind spot monitoring (BSM) control module (RH) terminal D and blind spot monitoring (BSM) warning light (RH) terminal D.<\/p>\n<ul type=\"disc\">\n                      <b>If there is a common connector:<\/b><\/p>\n<li>\n<p>Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.<\/p>\n<\/li>\n<li>\n<p>Repair or replace the malfunctioning part.<\/p>\n<\/li>\n<\/ul>\n<ul type=\"disc\">\n                      <b>If there is no common connector:<\/b><\/p>\n<li>\n<p>Repair or replace the wiring harness which has a short to ground.<\/p>\n<\/li>\n<\/ul>\n<p>Go to Step 5.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>4<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>INSPECT BLIND SPOT MONITORING (BSM) WARNING LIGHT (RH)<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Inspect the blind spot monitoring (BSM) warning light (RH).<\/p>\n<p>(See <a href=\"SM356066\">OUTER MIRROR GLASS INSPECTION<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Is the blind spot monitoring (BSM) warning light (RH) normal?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Replace the outer mirror glass (RH), then go to the next step.<\/p>\n<p>(See <a href=\"SM356061\">OUTER MIRROR GLASS REMOVAL<\/a>.)<\/p>\n<p>(See <a href=\"SM356062\">OUTER MIRROR GLASS INSTALLATION<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>5<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY THAT REPAIRS HAVE BEEN COMPLETED<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Always reconnect all disconnected connectors.<\/p>\n<\/li>\n<li>\n<p>Connect the negative battery cable.<\/p>\n<p>(See <a href=\"SM352783\">NEGATIVE BATTERY CABLE DISCONNECTION\/CONNECTION<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Clear the blind spot monitoring (BSM) control module DTCs using the M-MDS.<\/p>\n<p>(See <a href=\"SM353591\">CLEARING DTC [BLIND SPOT MONITORING (BSM) CONTROL MODULE]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Illuminate the blind spot monitoring (BSM) warning light (RH) using the simulation item WRN_IND_R.<\/p>\n<p>(See <a href=\"SM353621\">ACTIVE COMMAND MODES INSPECTION [BLIND SPOT MONITORING (BSM) CONTROL MODULE]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Retrieve the blind spot monitoring (BSM) control module DTCs using the M-MDS.<\/p>\n<p>(See <a href=\"SM353590\">DTC INSPECTION [BLIND SPOT MONITORING (BSM) CONTROL MODULE]<\/a>.)<\/p>\n<\/li>\n<li>\n<p>Is the same DTC displayed?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repeat the inspection from Step 1.<\/p>\n<ul type=\"disc\">\n<li>\n<p>If the malfunction recurs, replace the blind spot monitoring (BSM) control module.<\/p>\n<p>(See <a href=\"SM353678\">BLIND SPOT MONITORING (BSM) CONTROL MODULE REMOVAL\/INSTALLATION<\/a>.)<\/p>\n<\/li>\n<\/ul>\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Go to the next step.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n<p>6<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"2\" colspan=\"NaN\">\n                  <b>VERIFY IF OTHER DTCs DISPLAYED<\/b><\/p>\n<ul type=\"disc\">\n<li>\n<p>Are any other DTCs displayed?<\/p>\n<\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Yes<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.<\/p>\n<p>(See <a href=\"SM353592\">DTC TABLE [BLIND SPOT MONITORING (BSM) CONTROL MODULE]<\/a>.)<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"\" align=\"\" cellspacing=\"\" rowspan=\"\">\n<td valign=\"top\" align=\"center\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>No<\/p>\n<\/td>\n<td valign=\"top\" align=\"left\" cellspacing=\"\" rowspan=\"\" colspan=\"NaN\">\n<p>DTC troubleshooting completed.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\n          <a class=\"prevPage\" href=\"SM353592\">&lt; Previous<\/a> <a class=\"nextPage\" href=\"SM353594\">Next &gt;<\/a><\/p>\n<div align=\"right\">\n            <a href=\"\"#\">Back to Top<\/a>\n          <\/div>\n<div align=\"center\">\n            <em>\u00a9 2014 Mazda North American Operations, U.S.A.<\/em>\n          <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&lt; Previous Next &gt; 2016 &#8211; MX-5 &#8211; i-ACTIVSENSE DTC B11CB:11 [BLIND SPOT MONITORING (BSM) CONTROL MODULE] CAUTION: When replacing a blind spot monitoring (BSM) control module (RH) having any of the following part numbers, it is necessary to replace the blind spot monitoring (BSM) control module (LH) at the same time to perform the configuration normally. N243-67Y80 A N243-67Y80 B N243-67Y80 C Description Blind spot monitoring (BSM) warning light (RH) circuit malfunction Detection condition [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-9920","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9920","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/comments?post=9920"}],"version-history":[{"count":0,"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/pages\/9920\/revisions"}],"wp:attachment":[{"href":"https:\/\/chroot-me.in\/16ND\/wp-json\/wp\/v2\/media?parent=9920"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}