PURGE SOLENOID VALVE INSPECTION [SKYACTIV-G 1.3, SKYACTIV-G 1.5]
id0116q1800900
Airflow Inspection
1. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION.)
2. Remove the plug hole plate. (See PLUG HOLE PLATE REMOVAL/INSTALLATION [SKYACTIV-G 1.3, SKYACTIV-G 1.5].)
3. Remove the purge solenoid valve. (See PURGE SOLENOID VALVE REMOVAL/INSTALLATION [SKYACTIV-G 1.3, SKYACTIV-G 1.5].)
4. Inspect airflow between the ports under the following conditions.
am2zzw00012351
|
Measured condition |
Continuity between ports A—B |
---|---|
When voltage is not applied between terminals A and B
|
No airflow
|
When voltage is applied between terminals A and B
|
Airflow detected
|