PURGE SOLENOID VALVE INSPECTION [SKYACTIV-G 1.3, SKYACTIV-G 1.5]


id0116q1800900


Airflow Inspection

1.  Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION.)

2.  Remove the plug hole plate. (See PLUG HOLE PLATE REMOVAL/INSTALLATION [SKYACTIV-G 1.3, SKYACTIV-G 1.5].)

3.  Remove the purge solenoid valve. (See PURGE SOLENOID VALVE REMOVAL/INSTALLATION [SKYACTIV-G 1.3, SKYACTIV-G 1.5].)

4.  Inspect airflow between the ports under the following conditions.

am2zzw00012351

Measured condition

Continuity between ports A—B

When voltage is not applied between terminals A and B
No airflow
When voltage is applied between terminals A and B
Airflow detected

•  If not as specified, replace the purge solenoid valve. (See PURGE SOLENOID VALVE REMOVAL/INSTALLATION [SKYACTIV-G 1.3, SKYACTIV-G 1.5].)