DTC B112A:11 [START STOP UNIT]


id0902p6020400

Description

IG2 relay circuit malfunction

Detection condition
•  Start stop unit detects the IG2 relay output monitor voltage of 2.5 V or less for 0.5 s or more with the ignition switched ON (engine off or on).
Fail-safe function
Not applicable
Possible cause
•  Start stop unit connector or terminal malfunction
•  Start stop unit malfunction
System wiring diagram
Not applicable

Diagnostic Procedure

Step

Inspection

Action

1
VERIFY IF OTHER DTCs DISPLAYED FOR START STOP UNIT
•  Clear the DTC for the start stop unit using the M-MDS.
•  Retrieve the start stop unit DTCs using the M-MDS.
•  Are any other DTCs displayed?
Yes
Replace the start stop unit, then go to the Step 4.
No
Go to the next step.
2
INSPECT START STOP UNIT CONNECTOR CONDITION
•  Disconnect the start stop unit connector.
•  Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
•  Is the connector normal?
Yes
Go to the next step.
No
Repair or replace the connector, then go to the next step.
3
PERFORM DTC INSPECTION AND VERIFY IG2 RELAY MALFUNCTION
•  Always reconnect all disconnected connectors.
•  Reconnect the negative battery cable.
•  Clear the DTC for the start stop unit using the M-MDS.
•  Switch the ignition ON (engine off or on) and wait for 0.5 s or more.
•  Retrieve the start stop unit DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Replace the start stop unit, then go to the next step.
No
DTC troubleshooting completed.
4
VERIFY THAT REPAIRS HAVE BEEN COMPLETED
•  Clear the DTC for the start stop unit using the M-MDS.
•  Switch the ignition ON (engine off or on) and wait for 0.5 s or more.
•  Retrieve the start stop unit DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the start stop unit.
No
DTC troubleshooting completed.