DETERMINING SHORT TO GROUND LOCATION (MS-CAN) [SKYACTIV-D 1.5]
id100218000900
System Wiring Diagram
am2zzw00008220
|
Determination Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-37 AND INSTRUMENT CLUSTER
• Disconnect the negative battery cable.
• Disconnect the connector C-37.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 3.
|
||
2
|
INSPECT CAN LINE IN INSTRUMENT CLUSTER FOR SHORT TO GROUND
• Disconnect the instrument cluster connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the instrument cluster and connector C-37 because the wiring harness is shorted to ground.
|
No
|
Replace the instrument cluster because there is a short to ground in the instrument cluster.
|
||
3
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTORS C-37 AND DLC-2
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between connector C-37 and DLC-2 because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
4
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR C-37 AND CONNECTOR C-07
• Connect connector C-37.
• Disconnect connector C-07.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between connector C-37 and connector C-07 because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
5
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTOR CONNECTORS C-48 AND C-49 AND CONNECTOR C-07
• Connect connector C-07.
• Disconnect connectors C-48 and C-49.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between connector C-07 and connectors C-48 and C-49 because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
6
|
INSPECT FOR SHORT TO GROUND BETWEEN BLIND SPOT MONITORING (BSM) CONTROL MODULE (LH) AND CONNECTORS C-48 AND C-49
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 8.
|
||
7
|
INSPECT CAN LINE IN BLIND SPOT MONITORING (BSM) CONTROL MODULE (LH) FOR SHORT TO GROUND
• Disconnect the blind spot monitoring (BSM) control module (LH) connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the blind spot monitoring (BSM) control module (LH) and connectors C-48 AND C-49 because the wiring harness is shorted to ground.
|
No
|
Replace the blind spot monitoring (BSM) control module (LH) because there is a short to ground in the blind spot monitoring (BSM) control module (LH).
|
||
8
|
INSPECT FOR SHORT TO GROUND BETWEEN CONNECTORS C-48 AND C-49 AND CONNECTOR C-08
• Connect connectors C-48 and C-49.
• Connect connector C-08.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between connectors C-48 and C-49 and connector C-08 because the wiring harness is shorted to ground.
|
No
|
Go to the next step.
|
||
9
|
INSPECT CAN LINE IN CLIMATE CONTROL UNIT FOR SHORT TO GROUND
• Disconnect the climate control unit connector.
• Inspect for continuity at the following terminals:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness between the climate control unit and connector C-08 because the wiring harness is shorted to ground.
|
No
|
Replace the climate control unit because there is a short to ground in the climate control unit.
|